DTC P0097 | Intake air temperature (IAT) sensor No.2 circuit low input |
---|---|
DETECTION CONDITION
|
• The PCM monitors the IAT sensor No.2 signal. If the voltage at PCM terminal 242 remains low, the PCM determines that there is an IAT sensor No.2 circuit problem.
|
POSSIBLE CAUSE
|
• IAT sensor NO.2 malfunction
• Connector or terminal malfunction
• Short to ground in the wiring harness between IAT sensor NO.2 terminal B and PCM terminal 242
• PCM malfunction
|